BORDEN INC -- ELMER'S CRAFT BOND TACKY GLUE, E430 -- 8040-00N088091
=====================  Product Identification  =====================

Product ID:ELMER'S CRAFT BOND TACKY GLUE, E430
MSDS Date:02/20/1996
FSC:8040
NIIN:00N088091
=== Responsible Party ===
Company Name:BORDEN INC
Address:180 EAST BROAD ST
City:COLUMBUS
State:OH
ZIP:43215
Country:US
Info Phone Num:614-431-6680
Emergency Phone Num:614-431-6600
CAGE:07982
=== Contractor Identification ===
Company Name:BORDEN CHEMICAL CO
Address:180 E BROAD ST
Box:City:COLUMBUS
State:OH
ZIP:43215-3705
Country:US
Phone:614-225-6124
CAGE:86142
Company Name:BORDEN INC
Address:180 E BROAD ST
Box:208
City:COLUMBUS
State:OH
ZIP:43215-3705
Country:US
Phone:614-225-6124
CAGE:07982

=============  Composition/Information on Ingredients  =============

Ingred Name:NON-HAZARDOUS INGREDIENTS
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN ABSORPTION: NO HAZS KNOWN
    TO MFR. INGEST: NOT EXPECTED TO BE HARMFUL UNDER NORM CNDTNS OF
    USE. INHAL: NOT EXPECTED TO BE HARMFUL UNDER NORM CNDTNS OF USE,
    HOWEVER, IF ALLOWED TO BECOME AIR BORNE, MAY CAUSE IRRIT OF NOSE,
    THROAT & LUNGS. SKIN/EYE CONT: MAY CAUSE IRRIT ON PRLNG/RPTD CONT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGESTION: IF ACCIDENTLY SWALLOWED, DILUTE BY DRINKING LARGE
    QUANTITIES OF WATER. IMMEDIATELY CONTACT POISON CONTROL CENTER OR
    HOSPITAL EMERGENCY ROOM FOR ANY OTHER ADDITIONAL TREATMENT
    DIRECTIONS. IN HALATION: REMOVE TO FRESH AIR. SKIN: INCASE OF
    IRRITATION, FLUSH WITH WATER. EYES: IMMEDIATELY FLUSH WITH PLENTY
    OF WATER FOR AT LEAST 15 MINUTES. CALL MD IF IRRITATION PERSISTS.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WILL NOT BURN UNLESS WATER HAS EVAPORATED. USE
    MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT . IN CASE OF FIRE, WATER SHOULD BE USED TO KEEP
    FIRE-EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SOAK UP WITH ABSORBENT MATERIAL AND REMOVE TO
    A CHEMICAL DISPOSAL AREA. PREVENT ENTRY INTO NATURAL BODIES OF
    WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP FROM FREEZING. STORE IN A COOL,
    DRY PLACE. KEEP CONTAINERS TIGHTLY CLOSED. AVOID PROLONGED OR
    REPEATED BREATHING OF VAPOR.
Other Precautions:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN AND
    EYES. HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE AND SAFETY
    PRACTICES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WHERE AIR CONTAMINANTS CAN EXCEED ACCEPTABLE
    CRITERIA, USE NIOSH APPROVED RESP PROT EQUIPMENT. RESPS SHOULD BE
    SELECTED BASED ON FORM & CONCENTRATION OF CONTAMINANTS IN AIR I/A/W
    OSHA 29 CFR 1910.134/ OTHER APPLICABLE STANDARDS/GUIDELINES.
Ventilation:IF AIRBORNE CONTAMINANTS ARE GENERATED WHEN MATL IS
    HEATED/HANDLED, SUFFICIENT VENT IN VOL & AIR FLOW PATTERNS (SUP
    DAT)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VENT: SHOULD BE PROVIDED TO KEEP AIR CONTAMINANT CONC LEVELS BELOW
    ACCEPTABLE CRITERIA.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Vapor Pres:17.5 @ 20C
Vapor Density:<1
Spec Gravity:1.07
pH:5.1
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:DISPERSIBLE
Appearance and Odor:MILKY WHITE GET WITH MILD ACETIC AROMA
Percent Volatiles by Volume:48

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS AND ALKALINE MATERIALS.
Stability Condition to Avoid:NORMALLY STABLE AS DEFINED IN NFPA 704-12
    (4-3.1).
Hazardous Decomposition Products:DECOMPOSITION PRODUCTS MAY INCLUDE
    CARBON MONOXIDE AND CARBON DIOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:RECOVER FREE LIQUID. ABSORB RESIDUE AND DISPOSE
    OF ACCORDING TO LOCAL, STATE, AND FEDERAL REQUIREMENTS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.